358 g headset
3,185 nits brightness
200 Hz eye tracking
Custom designed and developed by RadiusXR®, InspirePRO™ combines patient-specific optics, adaptable fit components and environmental controls to support individualized alignment, patient comfort and a more confident testing setup.
At 358 g, its portable form factor brings advanced clinical capability into a patient-worn experience designed to move between rooms and care settings.
Tablet-driven portability
Independent −7 to +3 D correction and 54–71 mm IPD adjustment allow each optical channel to be positioned around the individual patient.
Dial-Fit and disposable neoprene strap configurations support different patients, workflows and hygiene requirements.
Standard and Wide modular light seals help control outside light, while integrated sound-isolation speakers reduce distractions during testing.
InspirePRO runs a screening visual field, pupillary light reflex, extraocular motility and cover-uncover alignment back to back in a single headset placement.
The sequence is technician-run. Both eyes are tracked throughout, and the results reach the chart as a one-page pre-testing report for the clinician to interpret.
InspirePRO supports full-measurement range under photopic testing conditions, bringing the clinical range required for early through advanced glaucoma into a portable headset.
HFA data import supports longitudinal review and continuity of care within the connected RadiusXR® platform, helping clinicians move to new hardware without leaving eligible patient history behind.
InspirePRO™ brings the full measurement range under photopic testing conditions into a custom-designed wearable perimeter. Download the brochure to explore its clinical capabilities, technology and key specifications.
Tablet-driven portability
Our purpose-built portable VRP headset combines cutting-edge vision diagnostics, business management tools, and patient engagement library in a single wearable spatial computing device. This headset helps streamline operations without compromising accuracy, enhances patient engagement and education while requiring minimal supervision.
Tablet-driven portability
A peer-reviewed and clinically-proven, virtual reality perimeter and spatial computing device delivering a suite of practice management tools and precision diagnostics.
A major leap in virtual reality perimeters. Just six ounces, it’s the lightest VRP — exclusively designed and developed by Radius.
RadiusXR partners with leading EMR and PACs to add performance and efficiency while enhancing practice workflow.
Introducing Inspire® by RadiusXR® — a virtual reality perimeter, the only VRP designed exclusively for eye care diagnostics. Weighing a mere six ounces and fitting seamlessly like a pair of sunglasses, it offers unparalleled comfort and precision. With statistical non-inferiority to current clinical standards for sensitivities at individual test locations, high concordance in glaucoma staging using Medicare definitions, and an exceptionally high correlation of 0.94 mean deviation, RadiusXR sets a new standard in ocular health technology.
Integrated applications allow clinicians to order exams and monitor progress in real-time from anywhere, set customizable thresholds, receive alerts to maintain reliability indices, and enhance patient outcomes with seamless efficiency.
We are raising the benchmark in visual field testing with customized software that facilitates advanced diagnostic capabilities with unrivaled accuracy and seamless integration
Trend Analysis
Elevate diagnostic insights and track progression with comprehensive data visualization tools. View individual exam reports alongside trend analysis for Mean Deviation (MD), Pattern Standard Deviation (PSD), and Visual Field Index (VFI).
Merging Exams
Merged exam report combines data from multiple exams into a single, high-resolution report. Seamlessly interpret exams with enhanced clarity and precision, revolutionizing diagnostic capabilities.
Pointwise Progression Analysis™ (PPA™)
RadiusXR’s innovative Pointwise Progression Analysis™ (PPA™) transforms clinicians’ monitoring of glaucoma progression by uniting trend-based and event-based insights. PPA analyzes changes at each test location, pinpointing areas with significant rates of visual field deterioration. Our proprietary method highlights meaningful patterns of change, enabling clinicians to assess progression with unparalleled precision while retaining complete control over clinical decision-making.
Change Analysis
Precision change analysis tools detect progression by comparing merged baseline and post-baseline visual fields. Confidently monitor patient progression with advanced analysis features.
InLive
Experience the future of patient exam monitoring with Radius InLiveTM. InLive provides a dynamic view of exam progress, precisely tracking trial presentation to the testing eye — along with patient responses — and adherence to age-matched threshold curves.

Dashboard
A dynamically customizable dashboard transforms exam monitoring and patient management. Real-time insights and customizable alerts create more confidence for clinicians at the point of decision-making, which is anywhere a tablet can go.






Our platform seamlessly integrates with Electronic Health Records (EHR) systems, ensuring compatibility with existing workflows while adhering to DICOM conformance standards, plus support for FHIR connect, HL7, and DICOM Modality Worklist (DMWL).
Customize and streamline the order creation process to bypass repetitive configuration steps. With just a few clicks, clinicians can expedite workflow, reduce administrative burden, and focus more time on patient care.
Designed to streamline repeatable exams, our templates combine routine exam strategies with enhanced patient adherence, resulting in improved efficiency and patient outcomes.
Enhanced 2fa with mobile-based one-time passcodes and seamless Single Sign-On (SSO) for Microsoft Azure and Google Workspace.
Expanded interoperability through support for DICOM, HL7, and FHIR standards.